Ikr 251 . Compact Cold Cathode gauge IKR 251 Functional Principle Over the whole measurement range, the measuring signal is output as a logarithm of the pressure The Pfeiffer Vacuum IKR 251 Compact Cold Cathode Gauge has been designed for vacuum measurement within a pressure range between 2 × 10^(-9) to 1 × 10^(-2) hPa
PFEIFFER IKR251 COLD CATHODE PENNING GAUGE from fergutec.com
Pfeiffer IKR 251 Cold Cathode Vacuum Gauge Transmitter Metal Sealed, KF25 23(5$7,1* ,16758&7,216 7udqvodwlrq ri wkh ruljlqdo lqvwuxfwlrqv ,.5 &rpsdfw &rog &dwkrgh *dxjh )30 jhglfkwhw
PFEIFFER IKR251 COLD CATHODE PENNING GAUGE The IKR 251 Cold Cathode Transmitter can be used either with a Pfeiffer Vacuum measurement unit for compact gauges or with another pressure evaluation unit. Add to cart shopping_cart Compare product compare_arrows The vacuum pressure can be displayed via a DCU or TCP 350 turbopump controller or via the TPG 261, 262, or 256.
Source: www.ebay.com PFEIFFER VACUUM IKR 251 COMPACT COLD CATHODE GAUGE eBay , Pfeiffer IKR 251 Cold Cathode Vacuum Gauge Transmitter Metal Sealed, KF25 Flange size DN 25 ISO-KF; The maximum pressure applies to inert gases and temperatures below 55 °C; Cold cathode (inverted magnetron) Rugged and dependable; Insensitive to air ingress; Corrosion resistant; Order number: PT R25 500 Flange size DN 25 ISO-KF.
Source: sparesby4030.com Compact Cold Cathode gauge IKR 251 , The Compact Cold Cathode Gauge IKR 251 has been designed for vacuum measurement in a pressure range of 2×10-9 The IKR 251 can be used with a Pfeiffer Vacuum measurement unit for Compact Gauges or with another evaluation unit
Source: www.highvacuumcompany.com Pfeiffer IKR 251, FPM sealed, DN 40 CFF , PT R25 500 IKR 251, DN 25 ISO-KF PT R25 501 IKR 251, DN 40 ISO-KF PT R25 502 IKR 251, DN 40 CF-F Tbl 2: Variants You can find the part number on the rating plate of the product
Source: www.recycledgoods.com Pfeiffer IKR 251 Cold Cathode Gauge PTR25500 FlangeDN 25 ISOKF NO , Functional Principle Over the whole measurement range, the measuring signal is output as a logarithm of the pressure 2: Variants You can find the part number on the rating plate of the product
Source: fergutec.com PFEIFFER IKR251 COLD CATHODE PENNING GAUGE , PT R25 500 IKR 251, DN 25 ISO-KF PT R25 501 IKR 251, DN 40 ISO-KF PT R25 502 IKR 251, DN 40 CF-F Tbl The IKR 251 Cold Cathode Transmitter can be used either with a Pfeiffer Vacuum measurement unit for compact gauges or with another pressure evaluation unit.
Source: sparesby4030.com Compact Cold Cathode gauge IKR 251 , PT R25 500 IKR 251, DN 25 ISO-KF PT R25 501 IKR 251, DN 40 ISO-KF PT R25 502 IKR 251, DN 40 CF-F Tbl These Pfeiffer IKR 251 Cold Cathode Gauges provide measurable vacuum pressure in the range 7.5x10-3 to 1.5x10-9 Torr
Source: www.recycledgoods.com Pfeiffer IKR 251 Cold Cathode Gauge PTR25500 FlangeDN 25 ISOKF NO , Add to cart shopping_cart Compare product compare_arrows The Compact Cold Cathode Gauge IKR 251 has been designed for vacuum measurement in a pressure range of 2×10-9
Source: www.ebay.com PFEIFFER IKR 251 HIGH VACUUM COMPACT COLD CATHODE GAUGE PTR25500 eBay , Pfeiffer IKR 251 Cold Cathode Vacuum Gauge Transmitter Metal Sealed, KF25 The IKR 251 can be used with a Pfeiffer Vacuum measurement unit for Compact Gauges or with another evaluation unit
Source: www.ebay.com PFEIFFER IKR 251 HIGH VACUUM COMPACT COLD CATHODE GAUGE PTR25500 eBay , The vacuum pressure can be displayed via a DCU or TCP 350 turbopump controller or via the TPG 261, 262, or 256. Functional Principle Over the whole measurement range, the measuring signal is output as a logarithm of the pressure
Source: multiprod-vacuum.ro IKR 251, Active Cold Cathode Transmitter DN 40 ISOKF Multiprod Vacuum , The vacuum pressure can be displayed via a DCU or TCP 350 turbopump controller or via the TPG 261, 262, or 256 Active Gauge controllers. pt r25 500 ikr 251,dn 25 iso-kf pt r25 501 ikr 251,dn 40 iso-kf pt r25 502 ikr 251,dn 40 cf-f 表格2: 类型 您可以在产品的铭牌上找到零件编号。 普发真空保留在未事先通知的情况下进行技术变更的权利。 已相应指示仅与其中一种设备有关的信息。 本文件中的图形未按比例绘制。
Source: www.ajvs.com New Pfeiffer Vacuum IKR 251 Cold Cathode Transmitter, DN 25 KF, FPM , Page 3: Table Of Contents 3 Installation 3.1 Vacuum Connection 3.1.1 Removing the Magnet Unit (Only for Gauges. The vacuum pressure can be displayed via a DCU or TCP 350 turbopump controller or via the TPG 261, 262, or 256.
Source: www.fergutec.com PFEIFFER IKR251 COLD CATHODE PENNING GAUGE , 2: Variants You can find the part number on the rating plate of the product The vacuum pressure can be displayed via a DCU or TCP 350 turbopump controller or via the TPG 261, 262, or 256.
Source: www.recycledgoods.com Pfeiffer IKR 251 Cold Cathode Gauge PTR25500 FlangeDN 25 ISOKF NO , pt r25 500 ikr 251,dn 25 iso-kf pt r25 501 ikr 251,dn 40 iso-kf pt r25 502 ikr 251,dn 40 cf-f 表格2: 类型 您可以在产品的铭牌上找到零件编号。 普发真空保留在未事先通知的情况下进行技术变更的权利。 已相应指示仅与其中一种设备有关的信息。 本文件中的图形未按比例绘制。 Flange size DN 25 ISO-KF; The maximum pressure applies to inert gases and temperatures below 55 °C; Cold cathode (inverted magnetron) Rugged and dependable; Insensitive to air ingress; Corrosion resistant; Order number: PT.
Source: www.ebay.com PFEIFFER IKR 251 HIGH VACUUM COMPACT COLD CATHODE GAUGE PTR25500 eBay , Over the whole measurement range, the measuring signal is output as a logarithm of the pressure. 2: Variants You can find the part number on the rating plate of the product
Source: www.recycledgoods.com Pfeiffer IKR 251 Cold Cathode Gauge PTR25500 FlangeDN 25 ISOKF NO , The vacuum pressure can be displayed via a DCU or TCP 350 turbopump controller or via the TPG 261, 262, or 256. The Compact Cold Cathode Gauge IKR 251 has been designed for vacuum measurement in a pressure range of 2×10-9
StrataVac + IKR 251 Medium/High Vacuum Controller Innovac Services LLC . The Compact Cold Cathode Gauge IKR 251 has been designed for vacuum measurement in a pressure range of 2×10-9 The IKR 251 Cold Cathode Transmitter can be used either with a Pfeiffer Vacuum measurement unit for compact gauges or with another pressure evaluation unit.
New Pfeiffer Vacuum IKR 251 Cold Cathode Transmitter, DN 40 KF, FPM . Over the whole measurement range, the measuring signal is output as a logarithm of the pressure. Page 3: Table Of Contents 3 Installation 3.1 Vacuum Connection 3.1.1 Removing the Magnet Unit (Only for Gauges.